ISO/TS 19036:2006/Amd.1:2009(E)
The test result may be reported according to one of the following possibilities:
(cfu/g)];
2,0 ± 0,3 [log 10
2,0 [log 10
(cfu/g)] [1,7; 2,3];
100 cfu/g [46; 220];
100 cfu/g [ − 54 %; + 120 %].
Applicable only if two formulae are used (see 8.2.2): C lim
= 144. Then, as Σ C = 11 < C lim
NOTE
= 144, simplified Equation (2) for
high counts cannot be used.
EXAMPLE 4 (applicable only if two formulae are used)
A standard deviation of reproducibility, s R
, of 0,22 [log 10
(cfu/g)] has been found.
C lim
= 36. Then, if Σ C > C lim
= 36, simplified Equation (2) for high counts, U = 2 × 0,22 = 0,44 applies.
A general rule, applicable only for results with Σ C > 36, may be stated according to one of the following possibilities:
(cfu/g)];
log result ± 0,44 [log 10
log result [log 10
(cfu/g)] [log result − 0,44; log result + 0,44];
result cfu/g [10 log result − 0,44 ; 10 log result + 0,44 ];
result cfu/g [ − 64 %; + 175 %].
If Σ C u 36, or if a single universally applicable equation is preferred, use Equation (1).”