2015.14 (JULY 2018) BVit‐02 Total Bs ERP Evaluation Form
FOR ERP USE ONLY DO NOT DISTRIBUTE
Evaluation of Method Performance vs. SMPR requirements.
AOAC SMPR: 2015.002, 2015.003, 2015.004, and 2015.005
BVIT‐02
Method Reference #
Simultaneous Determination of Total Vitamin B6, B2, B3 and B1 in Infant Formula Products by LC‐ MS/MS using Enzyme Digestion Samples are enzymatically digested with a stable isotope labeled internal standard and analyzed by LC‐MS/MS.
Method title:
Principle of the method:
Weighting factor for parameter
Suitability Ranking (1‐3‐5) (select from drop‐down list, 5 = best)
Method Performance Please report in units as stated in SMPR!
SMPR Requirement
Parameter
Applicable to all forms of infant, adult, and/or pediatric formula (powders, ready‐to‐feed liquids, and liquid concentrates). Any combination of milk, soy, rice, whey, hydrolyzed protein, starch, and amino acids, with and without intact protein.
All SPIFAN matrices evaluated met precision and accuracy requirements for all four vitamins. Precision = 14 matrixes evaluated Accuracy = 8 unique matrixes evaluated.
SPIFAN matrices
All analytes defined in the applicability statement are measured.
Method determines these four vitamins simultaneously from the same injection
Total B1, B2, B3, and B6
all units ug/100g of RTF
same same same
Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6 Total B1 Total B2 Total B3 Total B6
20 ‐ 2000 30 ‐ 4000
Analytical Range.
200 ‐ 10000
nearly same
10 ‐ 2000
9.79 8.65 95.2
≤ 20 ≤ 30
Limit of quantification (LOQ)
≤ 200
12.75
≤ 10
92.4 ‐ 102.5, mean 97.1% recovery 95.1 ‐ 100.7, mean 97.9% recovery 100.3 ‐ 110.7 , mean 103.8% recovery 96.8 ‐ 100.5, mean 99.1% recovery
Spike recovery (%)
90‐110 % mean spiked recovery over the Range
2.2% higher than certified 11.5% higher than certified 4.7% lower than certified 1.7% higher than certified
Bias vs SRM
Use SRM 1849a
1.1 2.3 1.2 1.5 3.4 5.1 2.8 4.4
≤ 5% ≤ 5% ≤ 5% ≤ 5%
Repeatability (RSDr)
not stated not stated not stated not stated
Intermediate Reproducibility (RSDiR)
not tested yet not tested yet not tested yet not tested yet
≤ 10% ≤ 10% ≤ 10% ≤ 10%
Reproducibility (RSDR)
ADDITIONAL EVALUATION PARAMETERS
Adequate proof of performance via system suitability
Feedback from Users of the Method since being awarded First Action Official Methods Status Did Method Author Consider ERP’s Method Specific Recommendations (See web link to specific method comments):
Bias against established method
Is there a bias Yes/No ?
Analytical equipment
Analytical equipment is commonly available in most labs.
Proprietary equipment
No unique proprietary equipment/accessories are required.
Laboratory safety
Method does not require any special safety precautions e.g. personal protection from highly toxic solvents.
Other Considerations
0
Overall Score
Decision by ERP
Recommendation of ERP 2 years after First Action Status
move to Final Action/repeal/remove/expand 2 year term
Notes:
a Concentrations apply to (1) "ready to feed liquids" "as‐is"; (2) reconstituted powders (25 g into 200 g water); and (3) liquid concentrates diluted 1:1 by weight.
b Units