AOAC ERP MICRO AUGUST 2018
OMAMAN-44 A: Collaborative Study Manuscript Expert Review Panel Use Only August 2018
for a LAB test, following procedures outlined in the Compendium of Methods for the Microbiological 480
Examination of Foods (16), to determine the total microbial load of the test matrix. The average LAB 481
result obtained by the collaborators was 4.1 x 10 6 CFU/g (1.7 x 10 5 CFU/g to 8.9 x 10 6 CFU/g). Appendix 482
483
Table 3 presents the results of the LAB for each collaborator.
484
Charm Peel Plate EB 24 Hours - Difference of means values (0.00, -0.16, 0.15 and 0.18) for the un-
inoculated, low, medium and high contamination levels, indicated that no statistical significant 485
difference existed between the candidate and alternative method. Repeatability (0.00, 0.33, 0.20 and 486
0.12) and reproducibility (0.00, 0.45, 0.26 and 0.18) values for each contamination level indicate that the 487
method performed similarly within sample replicates and between laboratories throughout the range of 488
489
contamination levels.
490
Charm Peel Plate EB 48 Hours - Difference of means values (0.00, -0.15, 0.16 and 0.18) for the
uninoculated, low, medium and high contamination levels, indicated that no statistical significant 491
difference existed between the candidate and alternative method. Repeatability (0.00, 0.34, 0.25 and 492
0.11) and reproducibility (0.00, 0.45, 0.25 and 0.17) values for each contamination level indicate that the 493
method performed similarly within sample replicates and between laboratories throughout the range of 494
495
contamination levels.
496
497
Collaborative Study Powdered Infant Formula with Probiotics Discussion
498
No negative feedback was reported to the study directors from the collaborating laboratories ERP Use Only regarding the performance of the candidate method. A few collaborators indicated that the Peel Plate 500 EB method produced distinct colonies and were very easy to read. 501 499
502
No statistically significant difference was observed between the candidate method, at both 24 and
48 h, and the ISO reference methods when compared using the difference of means of < 0.5. Difference 503
21