AOAC Final Action Methods in 2019

the temperature to allow the 3M Molecular Detection Heat Block Insert to reach and maintain a temperature of 100 ± 1°C. Note : Depending on the heater unit, allow approximately 30 min for the 3M Molecular Detection Heat Block Insert to reach temperature. Using an appropriate calibrated thermometer (e.g., a partial-immersion or digital thermocouple thermometer, but not a total-immersion thermometer) placed in the designated location, verify that the 3M Molecular Detection Heat Block Insert is at 100 ± 1°C. H. Preparation of the 3M Molecular Detection Instrument (a)  Launch the 3M Molecular Detection Software and log in. (b)  Turn on the 3M Molecular Detection Instrument. (c)  Create or edit a run with data for each sample. Refer to the 3M MDS User Manual for details. Note : The 3M Molecular Detection Instrument must reach and maintain a temperature of 60°C before inserting the 3M Molecular Detection Speed Loader Tray with reaction tubes. This heating step takes approximately 20 min and is indicated by an orange light on the instrument’s status bar. When the instrument is ready to start a run, the light on the status bar will turn green. I. Lysis (a)  Allow the LS tubes to warm up by setting the rack at room temperature (20–25°C) overnight (16–18 h). Alternatives to equilibrate the LS tubes to room temperature are to set the LS tubes on the laboratory bench for at least 2 h, incubate the LS tubes in a 37 ± 1°C incubator for 1 h, or to place the LS tubes in a dry double- block heater for 30 s at 100 ± 1°C. (b)  Invert the capped tubes to mix the content. Proceed to the next step within 4 h. (c)  Remove the enrichment broth from the incubator. (d)  One LS tube is required for each sample and the negative control (NC; sterile enrichment medium) sample. ( 1 ) LS tube strips can be cut to the desired LS tube number. Select the number of individual LS tubes or eight-tube strips needed. Place the LS tubes in an empty rack. ( 2 ) To avoid cross-contamination, decap one LS tube strip at a time and use a new pipet tip for each transfer step. ( 3 ) Transfer the enriched sample to the LS tubes specifically in the following order: Transfer each enriched sample into individual LS tube first. Then transfer the NC last. ( 4 ) Use the 3M Molecular Detection Cap/Decap Tool for lysis tubes to decap one LS tube strip one strip at a time. ( 5 ) Discard the LS tube cap. If lysate will be retained for a retest, place the caps in a clean container for reapplication after lysis. ( 6 ) Transfer 20 μL sample into an LS tube.

Table 2016.07C. Enrichment protocols using DF broth at 37 ± 1°C according to AOAC PTM Certificate No. 111501 a

Enrichment broth volume, mL

Enrichment time, h

Sample matrix

Sample size

Beef hot dogs, queso fresco, vanilla ice cream, 4% milk fat cottage cheese, 3% choco- late whole milk, romaine lettuce, bagged raw spinach, and cold smoked salmon

25 g

225

24–30

Raw chicken Deli turkey Cantaloupe b

25 g

475

28–32 24–30 26–30

125 g

1125

Whole melon Enough volume to allow the melon to float

Environmental samples  Stainless steel

1 Sponge 1 Sponge

225 100

24–30 24–30

 Sealed concrete

( 5 ) Homogenize thoroughly by mixing on a vortex mixer or stomaching for 2 ± 0.2 min. Incubate at 37 ± 1°C for 24–30 h. E. Preparation of the 3M Molecular Detection Speed Loader Tray (a)  Wet a cloth or paper towel with a 1–5% (v/v, in water) household bleach solution and wipe the 3M Molecular Detection Speed Loader Tray. (b)  Rinse the 3M Molecular Detection Speed Loader Tray with water. (c)  Use a disposable towel to wipe the 3M Molecular Detection Speed Loader Tray dry. (d)  Ensure the 3M Molecular Detection Speed Loader Tray is dry before use. F. Specific Instructions for Validated Methods AOAC INTERNATIONAL Performance Tested Method SM (PTM) 111501 .—In AOAC PTM studies, 3M MDA 2– Listeria was found to be an effective method for the detection of Listeria species. The matrixes tested in this study are shown in Table 2016.07C . The LOD for the 3M MDA 2– Listeria method is 1–5 CFU per validated test portion size in Table  2016.07C . G. Preparation of the 3M Molecular Detection Heat Block Insert Place the 3M Molecular Detection Heat Block Insert into the dry double-block heater unit. Turn on the dry block heater unit and set 24–30 a  All samples for the AOAC validation were homogenized by stomaching unless otherwise noted. b  Homogenize sample by hand-mixing. c  Homogenize sample by mixing on a vortex mixer.  Plastic c 1 Swab 10

Figure 2016.07A.

© 2017 AOAC INTERNATIONAL

Made with FlippingBook Learn more on our blog