AOAC OMA# 2011.14 (Final Action Review)-OMB
2011.14 (MTE-01) MLT FOR ERP USE ONLY DO NOT DISTRIBUTE
P oitevin : J ournal of AOAC I nternational V ol . 95, N o . 1, 2012 181
Table 2011.14E. Interlaboratory study results for magnesium Matrix Mean, mg/kg Rec., % S r , mg/kg a RSD r , % b S R
, mg/kg c RSD R
, % d
HorRat No. of labs e Outlier labs f
Chocolate milk powder Dietetic milk powder 2
1746.74 439.31 859.48
98 38.46 2.20 51.03
2.92 3.04 4.12 4.30
0.56 0.48 0.71 0.82
8 9 7 8
2–SG
NS g
99
5.57 1.27 13.37
Infant cereal
98 33.62 3.91 35.38
2,6–DG
1714.02 (1680) h 102 56.83 3.32 73.68
Peanut butter NIST SRM 2387 Wheat gluten NIST RM 8418
2–SG
482.05 (510) h
95
8.52
1.77
16.53
3.43
0.54
9
NS
a S r
= SD for repeatability (within laboratory).
b RSD r
= RSD for repeatability.
c S R
= SD for reproducibility (among laboratories).
matched standard calibrant solutions. An ionization buffer (cesium) and internal standards (chromium, indium, strontium, and yttrium) are used with or without appropriate in-line addition to minimize easily ionizable element (EIE) effects and to correct for physical and chemical interferences. = RSD for reproducibility. e Reporting laboratories minus outliers. f SG = Single Grubbs outlier; DG = Double Grubbs outlier. g NS = Not significant. h Certified or reference values. d RSD R
manufacturer’s directions for safety risk, safety environment, and use of instruments. ( a ) ICP-OES spectrometer . ____ Instrument with axial, radial, or dual view grating configurations and autosampler, capable of determining multiple wavelengths for each element of interest with the required sensitivity. A three-channel peristaltic pump with or without appropriate in-line addition system (e.g., T connector) are linked between the peristaltic pump and nebulizer to avoid having to manually add ionization buffer and internal standards to each sample solution. A thermostatted cyclonic spray chamber is equipped with a micro-concentric nebulizer or other components designed to optimize aerosol and maximize
F. Instrumentation
Note : ICP-OES equipment must be used by qualified laboratory personnel who are familiar with the operation and maintenance of analytical systems; personnel must follow
Table 2011.14F. Interlaboratory study results for manganese Matrix Mean, mg/kg Rec., % S r , mg/kg a RSD r , % b S R
, mg/kg c RSD R
, % d HorRat No. of labs e Outlier labs f
NA g
NS h
Chocolate milk powder Dietetic milk powder 2
7.54 0.40
0.14 1.88
0.67
8.82 4.89 8.61 8.31
0.75 0.27 0.82 0.79
9 8 9 9
99
0.01 2.56 0.0197
2 – C
Infant cereal
16.74
NA 1.14 6.79
1.44 1.32
NS NS
15.85 (16.0) i
Peanut butter NIST SRM 2387 Wheat gluten NIST RM 8418
99
0.45 2.86
12.87 (14.3) i
90
0.23
1.75
1.13
8.75
0.80
9
NS
a S r
= SD for repeatability (within laboratory).
b RSD r
= RSD for repeatability.
c S R
= SD for reproducibility (among laboratories).
d RSD R = RSD for reproducibility. e Reporting laboratories minus outliers.
f C = Cochran outlier. g NA = Not available. h NS = Not significant. i Certified or reference values.