AOAC OMB Final Action Recommendation (December 2019)-2016.14
2016.14 (October 2019) – FOS-03 METHOD
FOR ERP USE ONLY DO NOT DISTRIBUTE
127
FRUC, was used. When enzymes from another source are used, the buffer composition (type,
128
concentration and pH) may need to be adapted to the recommendations of the supplier. It is also
129
imperative to ensure the enzyme mixture will completely hydrolyse any sucrose in the product
130
without hydrolysing the fructans. This can be checked by performing an analysis with sucrose as
131
an analyte and with a pure fructan as an analyte. No fructan should be measured when sucrose is
132
analysed, and more than 90 % recovery should be achieved when a fructan of known purity is
133
analysed (recommended to check using both long chain inulin and short chain FOS). An alternative
134
test for checking the suitability and performance of the enzyme mixture is described in Appendix
135
A.
(k) Fructanase (exo-/endo-inulinases/endo-levanase) solution .—Dissolve the content of the bottle
136
containing freeze-dried powdered exo- and endo-inulinases and endo-levanase C(r) in 22.0 mL
137
sodium acetate buffer D(c) . Mix well and divide into aliquots of 2 mL each and store frozen at -
138
139
20 °C in polypropylene tubes until use. Stable for 5 years at -20 °C. NOTE: For the development
140
and validation of this method, the pre-prepared enzyme mixture available in the Megazyme kit K-
141
FRUC, was used. When enzymes from another source are used, buffer composition (type,
142
concentration and pH) may need to be adapted to the recommendations of the supplier. It is also
143
imperative to ensure the enzyme mixture will completely hydrolyse the fructan without
144
hydrolysing any other glucose or fructose containing oligo- or polysaccharide that may be present
145
after treatment with the sucrase mixture above. This can be checked by performing an analysis
146
with a pure fructan as an analyte. More than 90 % recovery should be achieved when a fructan of
147
known purity is measured.
(l) Wash solution for graphitized carbon SPE column (TFA 0.1 % in acetonitrile 80 % (v/v)) .—Into a
148
149
100-mL volumetric flask, add 80 mL acetonitrile and 100 μL TFA. Make up to the mark with water.
150
Stable for 6 months at room temperature.
7