AOAC RI ERP Final Action Recommendations eBook
Dupont BAX Salmonella PTM Report PTM Certification No. 081201 (08/07/2012) For Expert Review Panel Use Only Do Not Distribute
91 92 93 94 95 96 97 98
Agriculture Food Safety and Inspection Service (USDA-FSIS) [4]. These culture methods each
require at least three days for a negative result and often many more days if there are potential
or actual Salmonella present in an enriched matrix. Rapid methods for screening Salmonella
have been developed, but these generally require two days of enrichment. By contrast, the
BAX® System detects the pathogen approximately 1.5 hours after a 12-24 hour enrichment,
and the DNA-based results are both reliable and reproducible, leading to quicker release of
cleared product.
9. TEST KIT INFORMATION
99 100 101 102 103 104 105 106
Test kit name – BAX ® System Real-Time PCR Assay for Salmonella .
Test kit catalog number – D14306040
Ordering information –
DuPont Qualicon, Experimental Station, Bldg. 400, P.O. Box 80400, Rt. 141 & Henry Clay
Road, Wilmington, DE 19880-0400, USA, Phone 800-863-6842 or 302-695-5300, Fax 302-
695-5301, Internet www.qualicon.com
107
DuPont Qualicon Europe, Ltd Wedgwood Way, Stevenage Herts SG1 4QN, UK
108 109
DuPont Qualicon, Asia/Pacific DuPont Company (Singapore) Pte, Ltd. 1 Harbour Front Place
#11-01, Harbour Front Tower One, Singapore 098633
110 111 112 113 114 115 116 117 118 119 120 121
Test kit components –
AOAC INTERNATIONAL PCR tubes with tablets (twelve 8-tube strips, each tube containing 1 PCR tablet) Flat optical caps for PCR tubes (twelve 8-cap strips)
Lysis buffer (two 12-mL bottles)
Protease (one 400-µL vial)
Made with FlippingBook