AOAC RI ERP Final Action Recommendations eBook

Dupont BAX Salmonella PTM Report PTM Certification No. 081201 (08/07/2012) For Expert Review Panel Use Only Do Not Distribute

91 92 93 94 95 96 97 98

Agriculture Food Safety and Inspection Service (USDA-FSIS) [4]. These culture methods each

require at least three days for a negative result and often many more days if there are potential

or actual Salmonella present in an enriched matrix. Rapid methods for screening Salmonella

have been developed, but these generally require two days of enrichment. By contrast, the

BAX® System detects the pathogen approximately 1.5 hours after a 12-24 hour enrichment,

and the DNA-based results are both reliable and reproducible, leading to quicker release of

cleared product.

9. TEST KIT INFORMATION

99 100 101 102 103 104 105 106

Test kit name – BAX ® System Real-Time PCR Assay for Salmonella .

Test kit catalog number – D14306040

Ordering information –

DuPont Qualicon, Experimental Station, Bldg. 400, P.O. Box 80400, Rt. 141 & Henry Clay

Road, Wilmington, DE 19880-0400, USA, Phone 800-863-6842 or 302-695-5300, Fax 302-

695-5301, Internet www.qualicon.com

107

DuPont Qualicon Europe, Ltd Wedgwood Way, Stevenage Herts SG1 4QN, UK

108 109

DuPont Qualicon, Asia/Pacific DuPont Company (Singapore) Pte, Ltd. 1 Harbour Front Place

#11-01, Harbour Front Tower One, Singapore 098633

110 111 112 113 114 115 116 117 118 119 120 121

Test kit components –

AOAC INTERNATIONAL PCR tubes with tablets (twelve 8-tube strips, each tube containing 1 PCR tablet) Flat optical caps for PCR tubes (twelve 8-cap strips)

Lysis buffer (two 12-mL bottles)

Protease (one 400-µL vial)

Made with