Microsoft Word - 3M Petrifilm REC Plate OMA Manuscript 09121

ERP Methods Book

77

( d ) The counting range for E. coli on the 3M Petrifilm Rapid E. coli /Coliform Count Plate is  1 lower than or equal to 100 blue to blue‐green colonies with and without gas regardless of the  2

number of total colonies. The counting range for total coliforms on 3M Petrifilm Rapid E.  3

coli /Coliform Count Plate is lower than or equal to 100 colonies. The countable range for E. coli 4

or total coliform may occur on separate dilutions.  5 ( e ) 3M Petrifilm Rapid E. coli /Coliform Count Plates with colony counts too numerous to  6 count (TNTC) may have one or more of the following characteristics: lightening of the gel color  7

to yellow, many small, indistinct red or blue colonies and/or many gas bubbles. High  8

concentrations of E. coli or coliforms may cause the outer edge of the growth area to turn pink  9

to pink orange. When this occurs, record results as TNTC. For a more accurate count, further  10

11

dilution of the sample may be necessary. 

12

( f ) If the 3M Petrifilm Rapid E. coli /Coliform Count Plates cannot be counted within the 

incubation period, they may be stored for later enumeration by freezing in a sealable container  13

at temperatures lower than or equal to negative 15°C (5°F) for no longer than one week.  14 ( g ) For further information refer to the “3M™ Petrifilm™ Rapid E. coli /Coliform Count 15 Plate Interpretation Guide”. If you have questions about specific applications or procedures,  16

please visit our website at www.3M.com/foodsafety or contact your local 3M representative or  17

18

distributor.  

19

20 21

Confirmation   

11

December 6, 2018

Made with FlippingBook - Online Brochure Maker