Microsoft Word - Candidates for 2018 ERP of the Year
60
III. Kratom ( Mitragyna speciosa)
Kratom ERP Members Present: Darryl Sullivan, Covance (Chair); Joseph Betz, NIH; Nour Eddine Es-Safi, Mohammed V University in Rabat; Charles Metcalfe, Custom Analytics; Tom Phillips, State of MD; John Spzylka, Mérieux Nutrisciences; Yan-Hong Wang, University of Mississippi
Kratom ERP Members Absent: Christine Casey, FDA; Catherine Rimmer, NIST
AOAC Method #
Manuscript Title
ERP Recommendations on Methods
Consensus
Decision Date
KRA-01
Quantitative and Qualitative Analysis of Mitragynine in Kratom ( Mitragyna speciosa) by GC-MS, LC-MS/MS and UPLC-PDA
December 9, 2015
•
Commercially available standards from Chromadex for 7 OH
• • •
Need to see recovery data
Include 7 OH data
Range of quantification must cover whole range from SMPR Precision and accuracy data is needed across entire range of quantification Interest from ERP is in the tandem MS method LOD and LOQ information for 7- OH required. Repeatability must be improved More accuracy and recovery data
•
•
KRA-02
Quantification of Mitragynine in Kratom Raw Materials and Finished Products by
December 9, 2015
•
• • • •
High-Performance Liquid Chromatography: Singly Laboratory Validation
Peak purity PDA
MOTION to accept the requested actions as written for KRA-01, KRA-02, KRA-03, KRA-04. Motion by Szpylka, second by Metcalfe. 7 in favor, 0 opposed, 0 abstain. MOTION PASSED.
Examine additional wavelength data
KRA-03
Identification and Characterization of Indole and Oxindole Alkaloids from Leaves of Mitragyna speciosa Korth Using Liquid Chromatography-Accurate QToF Mass Spectrometry
December 9, 2015
•
Need precision and accuracy to demonstrate compliance with the SMPR.
KRA-04
LC/MS Method for the Identification of Mitragyna speciose (Kratom) and
December 9, 2015
•
Feedback on recoveries outside the SMPR Demonstration of precision data
•
03/12/2018