SPDS 09052014
8/22/2014
CPC Titration
– CPC cation forms ion pair with large CS anion – Ion pair has poor solubility and causes turbidity A t f t bidit i ti l t t – moun o ur y s propor ona o amoun of CS in solution and can be measure with optical sensor (phototrode) – Non‐Specific • Will react with any large polyanion • Small additions of hexametaphosphate will increase results dramatically • Can not be used as stand‐alone method; must be used in conjunction with appropriate identity and purity tests.
Outcome of WG Meeting on 3/21/14
• Proposed Fitness for Purpose Statements 1. Assay Method: Accurately quantify total CS in raw materials & finished products as a neat substance and in the presence of other ingredients 2. Identity Method (1): Accurately identify CS in raw materials & finished products and distinguish CS from economic adulterants 3. Identity Method (2): Accurately identify the source of CS in raw materials 4. Purity Method: Detect known adulterants in CS in raw materials & finished products at a specified level and confidence
13