Total Collaborative Study Protocol_Solus One Salmonella v1 1

Serological pipettes .— Aerosol resistant. 

( l ) 

( m )  Precision pipettes .— For sampling and delivering of 100–300 µL, and 200–1,000 µL. 

( n )  Micropipette tips .— Aerosol resistant. 

( o )  Multi‐channel pipette .— Capable of delivering 100–300 µL. 

( p )  Microplate washer .  ( q )  Microplate reader with 450nm filter .  ( r )  Calibrated Thermometers .— Capable of measuring a temperature of 37 ± 1°C, 41.5 ± 1°C, and 

85–100°C. 

( s )  Vortex mixer .— For swab homogenization. 

( t )  Calibrated Timer .  ( u )  Marker . 

Reference Materials 

Organisms used in the inclusivity/exclusivity and method comparison studies were obtained from 

the following sources: 

( a )  American Type Culture Collection (ATCC) .— Manassas, VA, 20110, USA. 

www.atcc.org.

( b )  The National Collection of Type Cultures (NCTC) .— Salisbury, SP4 0JG, UK. 

http://www.phe‐culturecollections.org.uk/collections/nctc.isp.

( c )  U.S. Food and Drug Administration Culture Collection (FDA) .— 10903 New Hampshire Avenue, 

Silver Spring, MD, 20993, USA.

Page 11 of 39