Method Performance Requirements Table 2: Method performance requirements (part 1) for cannabinoids

Parameter *

Requirement

Limit of Quantitation (LOQ)   (%) Analytical Range (CBD &  CBDA) (%)

≤   0.05  

0. 05 – 35

Analytical Range (others) (%)

0.05 – 5

*All calculated on dry weight basis

Table 3: Method performance requirements (part 2) for cannabinoids Method Performance Requirements

Ranges (%)

Parameters*

0.05 – 0.5   

> 0.5 ‐ 5   

5 ‐ 35

Recovery (%)

85 – 118

90 ‐ 111

95‐105

% RSD r % RSD R

≤ 5

≤ 3

≤ 2

≤ 8

≤ 6

≤ 4

*All calculated on dry  weight basis; observed  values to be compared  to indicated limits for  acceptability.

Only applicable  to CBD and  CBDA